NEW ARRIVAL

PRODUCT SEARCH






PRODUCT LIST

Jual Ventilator








Call

ALBE medical menjual MTV1000 Pneumacare. MTV1000 Pneumacare adalah Tipe Transportable Ventilator yang memiliki fitur High Performance Homecare Ventilator ( Peak Inspiratory Pressure up to 80cmH2O (above PEEP), FiO2 monitoring (real time monitoring), Optional SpO2 ), Wide Application, dan Transportable Function ( Low Flow O2 ).
Tipe ini berteknologi ACPAP+ (Adaptive CPAP Plus Pressure Support)®, ACPAP+ (Adaptive CPAP Plus Pressure Support)®, ABiPAP + (Adaptive BiPAP Plus Pressure Support), Benefit of EtCO2 option in Ventilator (Hemo-Dynamics) , Benefit of SpO2 Option in Ventilator, PRVC (Pressure Regulated Volume Ventilation), O2 Stream, dan Proximal Flow Sensor in Pneuma. Kelebihan Ventilator ini : Mudah digunakan (user friendly), layar Touch screen, dilengkapi internal battery yg tahan 3 jam, Aksesoris murah dan mudah di dapat 

 

 
Spesifikasi Umum : 
Kategori : Ventilator
Merk / Tipe : Mekant/ MTV-1000 Pneumacare
Negara Asal : Korea Selatan
Kondisi Barang : Baru
Berat

: 6.1kg (main unit)

Dimensi

: 25 x 15.6 x 37.1 (Width x Depth x Height) cm

Garansi : 1 Tahun

 

 

 

Spesifikasi Khusus : 

1. Short Form Specifications : Transport Ventilator (Home-Care, Ambulance, ER)
        : 7" Color TFT, Touch Screen & Knob
        : O2 LowFlow
     Mode Single Limb : PACV, ACPAP+, BiPAP+, O2 Stream®
      Optional : O2Stream® (Nasal Cannular), Sp)2
           * Additional Battery : Over 6 hours
2. Detalil Specifications
  2.1 Ventilator Data (Setting Parameters)
    Predicted Body weight   : 3 to 150kg (Pressure)
    Inspiratory pressure   : 5 to 80 cmH2O
    Pressure support   : 0 to 60 cmH2O
    Respiratory rate   : 2 to 60 bpm
    Inspiratory time   : 0.3 to 4 sec
    PEEP/CPAP  

: 0 to 45 cmH2O

    Enable inhalation trigger(En-sense) : 10 to 80% of set tidal volume
    Trigger sensitivity   : Pressure : OFF, 0.5 to 20 cmH2O
        : Flow : OFF, 0.5 to 20 lpm
    BTPS   : OFF, MANUAL DRY, MANUAL HUMIDI
    MASK   : ON / OFF
    MASK Type   : Full Face, Nasal, Pillow, User in  ACPAP+ and BiPAP+
    ACPAP+ Mode    
    PAP   : 3.0 to 20.0 cmH2O
    PS   : 0 to 60 cmH2O (PAP+PS < 80CmH2O depend on leakage flow)
    Exsense   : 1 to 80 %
    Brk   : 0.1 to 2.0 sec
    Ramp time   : OFF, 1 to 60 min
    Wake up   : ON/OFF
    ABIPAP+ Mode    
    I-PAP   : 3 to 45 cmH2O
    E-PAP   : 0 to 42 cmH2O
    Rate   : 2 to 30 bpm
    I-TIME   : 0.3 to 24.0 sec
    PS   : 0 to 45 cmH2O
    Exsense   : 1 to 80 %
    Brk time   : 0.1 to 2.0 sec
    Trigger sensitivity Pressure : OFF, 0.1 to 20 cmH2O
      Flow : OFF, 0.1 to 20 lpm
    O2 Stream Mode    
    Flow   : 5 to 50 lpm
    Inspiratory Pressure limit   : 5 to 80 cmH2O in O2 Stream
    Trigger sensitivity Pressure : OFF, 0.1 to 5.0 cmH2O
      Flow : OFF, 0.1 to 5.0 lpm
  2.2 Display Data
    Parameters   : Setting parameters/patient status parameters/Alarm status/I:E ratio
    Graphic Waveform  

: Pressure-Time, Flow-Time, Volume-Time

    Alarm   : Airway pressure, Tidal volume, Minute volume, Respiratory rate
        : Apnea, O2%, Airway leak, Circuit open, Battery indicator
        : O2 supply pressure failure, Ventilation in-operation
  2.3 Alarm Setting Parameters (MAIN)
    High tidal volume (Expiratory volume) : OFF, 20 to 2500 ml
    Low tidal volume (Expiratory volume) : OFF, 10 to 2400 ml
    High minute volume : 0.5 to 50 lpm
    (Expiratory minute volume)  
    Low minute volume : 0.0 to 49 lpm
    (Expiratory minute volume)  
    High respiration rate   : 2  to 150 bpm
    Low respiration rate   : 0  to 148 bpm
    High peak airway pressure   : OFF, 1 to 120 cmH20
    Low peak airway pressure   : OFF, 0 to 110 cmH20
    High O2%   : OFF, 0 to 100%
    Low O2%   : OFF, 0 to 80%
    Airway leak   : OFF, 10 to 500 ml
    Apnea   : OFF, 10 to 60 sec.
    (Option, SPO2)        
    High SpO2   : OFF, 52 to 100%
    Low SpO2   : OFF, 51 to 99%
    High pulse rate (SpO2)   : 30 to 250 bpm
    Low pulse rate (SpO2)   : 25 to 245 bpm
  2.4 Key, Indicators        
    Inspiration hold   : Measures patient's lung compliance and resistance
        : Elasticity, Time constant
    Key lock   : Key & LCD Touch Screen Lock
    Graph freeze        
    Alarm silence  

: Mutes audible alarms for 2 minutes

    Alarm reset   : Clears visual indicators and messages
  2.5 Electrical Requirements        
    Power   : AC : 100-230 VAC, 50/60 Hz (Free voltage)
        : DC : 10.8V 8.8A, Internal battery
            Provides Max. 180 minutes of normal operation
  2.6 Physical Characteristic        
    Weight   : 6.1 kg (main unit)
    Dimension   : 25 x 15.6 x 37.1 (Width x Depth x Height) cm
  2.7 Environmental Requirements        
    Atmospheric condition   : 700 to 1060 mbar (10.2 ~ 15.4 psi)
    Altitude   : -443 ~ 3048 m (-1350 ~ 10,000ft)
    Height   : Up to 6560 m (20,000 ft)
    Conditions of use   : 10 to 40 ℃ (50 ~ 104 ℉)
    Relative humidity   : 10 to 85%
  2.8 Pneumatic Requirements        
    Oxygen/Air inlet supply pressure   2.46 to 6.32 kgf/cm2 / 2.4 to 6.2 bar (35 to 90 psig)

 

 


Share This Page :

SHOWROOM ALBE
Jl. Taman Mini Indonesia Indah (TMII) Pintu II atas No. 9. Cipayung, Jakarta Timur - Jakarta, Indonesia
Fax : +62-021 840 7865. Phone: +62-021 841 5976, +62-21 877 93819  (Office Hours 09 Am - 4 Pm, Monday - Saturday) : Cellular : +62-8128097502 (Voice + SMS)
Email : marketing@alatkedokteran.id atau marketing_permana@yahoo.com